Autoclave Tomy Sx700 Manual Best [hot] Now
A critical concept for reliable sterilization is the . This refers to the delay between when the autoclave’s chamber reaches its set temperature and when the load's center reaches that same temperature. Failing to account for HTTL can lead to sterilization failure.
Tape the error code page to the wall next to the autoclave.
This comprehensive technical guide outlines the essential features, step-by-step operating protocols, programmatic cycles, and maintenance routines defined by the manufacturer to ensure your team achieves the best sterilization outcomes. Core Specifications & Physical Design autoclave tomy sx700 manual best
When the Tomy SX-700 encounters an operational anomaly, it halts the cycle and displays an alphanumeric error code. Here are the most common codes found in the manual and how to fix them:
The SX-700 shines because of its programmable memory (up to 7 custom programs). The manual defines the three default cycles: A critical concept for reliable sterilization is the
Never over-pack the baskets. Steam must circulate freely between items to ensure total sterilization.
The SX-700 panel features simple, single-action buttons to select from four distinct operational modes tailored to your specific media or materials. Target Load Type Process Flow Agar, water, culture media, nutrient broths →right arrow Sterilizing →right arrow Slow Venting →right arrow Liquid (No Warming) Buffers, reagents, heat-stable liquids →right arrow Sterilizing →right arrow Slow Venting →right arrow Natural Cooling Solid Sterilization Glassware, plastic tips, surgical instruments, empty flasks →right arrow Sterilizing →right arrow Rapid Venting →right arrow Completion Dissolution / Melting Coagulated agar media needing liquefaction →right arrow →right arrow Step-by-Step Guide to Running a Cycle Tape the error code page to the wall next to the autoclave
Do you have a specific SX-700 error code or cycle time question? Check Section 8 (Troubleshooting) or Section 12 (Cycle Parameters) of your official TOMY SX-700 manual. If you have lost your physical copy, contact TOMY customer support immediately with your serial number for a replacement PDF.
This guide consolidates the best practices from the to help you maximize the efficiency and lifespan of your unit. Core Specifications of the SX-700 Effective Capacity 69 Liters (79L total internal volume) Temperature Range 45°C to 135°C (Sterilization) Cooling System Standard dual-fan system (reduces cooling time by ~28 mins) Safety Features Lid interlock, water level sensor, exhaust bottle detector Power Requirements Single-phase 230V AC (15A or more) Operating Courses and Features
Have a specific SX-700 error code or cycle question? Consult your physical manual first—then check the official TOMY support forum for application notes.
Engage the foot pedal or slide the locking chassis into place (depending on the specific sub-generation design of the SX series).